Dumont SS/45 Long Angled Isolating Tweezers

£45.00 £54.00 inc VAT £36.00 £43.20 inc VAT

The Dumont Tweezers are known all over the world for their high quality, durability, and precision. Dumont Inox Eyelash Tweezers SS/45 are superb quality tweezers, ideal for creating beautiful fluffy fans.

These tweezers are recommended for lash artists who have honed their craft over time and operate their tweezers with a light touch.

  • These tweezers can be used as isolating tweezers or for making fans.
  • Length 13 cms
  • Original Swiss Dumont Tweezers of the highest precision.
  • Stainless steel.
  • Matte finish.
  • Very light, comfortable to use.
  • Excellent grip.

Please note we buy our Dumonts direct from Dumont in Switzerland and all our tweezers are made to order.

Time left to order via RM Next Day Delivery to get your order before Christmas (UK only)

In stock

Klarna badge Mastercard badge Maestro badge Visa badge Amex badge Discover badge
SKU: DUM-SS-/45-TWE Categories: , , Brand:
Like it, Tweet it, Pin it, Share it...

Description

45-degree tweezers with a long handle. These tweezers can be used as isolating tweezers or for making fans.

Care Instructions:

  • Do not soak in antibacterial liquid (i.e. Barbicide) as there is a risk of the tweezers rusting.
  • When the tweezers are not in use, always ensure the tips are protected with the rubber protector provided when purchased.
  • DO NOT drop them. The delicate tips will lose their precision if dropped.

Additional Information:

Care & Handling of Surgical Instruments.

Rinsing:

Immediately after use, rinse instruments under warm running water to remove all residue. If not cleaned immediately after rinsing, instruments should be submerged in a solution of water and neutral pH (7) detergent until they can be cleaned.

Cleaning:

  1. Ultrasonic Cleaning: Place instruments in an open position into the ultrasonic cleaner. Make sure that instruments with sharp blades (scissors, etc.) do not touch other instruments. All instruments must be fully submerged. Do not place dissimilar metals (stainless, copper, chrome plated, etc.) in the same cleaning cycle. Instruments should be processed in the cleaner for 5 to 10 minutes. After ultrasonic cleaning, rinse instruments with water to remove the ultrasonic cleaning solution.
  2. Automatic Washer Sterilizers: Follow manufacturer’s recommendations. Be sure to lubricate instruments after the last rinse cycle and before the sterilisation cycle.
  3. Manual cleaning: Ultrasonic cleaning is the most effective way to clean surgical instruments, especially those with hinges, locks, and moving parts. If ultrasonic cleaning is not available, follow these steps:
  • Use stiff plastic cleaning brushes. Do not use steel wool or wire brushes.
  • Use only neutral pH (7) detergents. (Low pH detergents, if not rinsed off properly, will cause the breakdown of stainless protective surface and black staining. High pH detergents will cause surface deposit of brown stain, which will also interfere with the smooth operation of the instrument.)
  • Brush delicate instruments carefully and, if possible, handle them separately from general instruments.
  • Make sure all instrument surfaces are visibly clean and free from stains and tissue. Inspect each instrument for proper function and condition. Make sure that scissor blades glide smoothly all the way (blades must not be loose when in a closed position). Check that forceps tips are properly aligned. Make sure that hemostats and needle holders do not show light between the jaws, that they lock and unlock easily, and that the joints are not too loose. Check needle holder jaws for wear. Examine cutting instruments and knives to be sure their blades are sharp and undamaged.
  • After scrubbing, rinse instruments thoroughly under running water. While rinsing, open and close scissors, hemostats, needle holders, and other hinged instruments to ensure those hinge areas are also rinsed out.

Autoclaving:

  • Lubricate all instruments which have any metal-to-metal action such as scissors, hemostats, needle holders, self retaining retractors, etc. Surgical instrument lubricants should be used. Do not use WD-40 oil or other industrial lubricants.
  • Instruments may be autoclaved individually or in sets. Individual instruments—Disposable paper or plastic pouches are ideal. Make sure you use a wide enough pouch (4” or wider) for instruments with ratchet locks (such as needles holders and hemostats) so the instrument can be sterilized in an open (unlocked) position. Instrument Sets—Unlock all instruments and sterilize them in an open position. Place heavy instruments on the bottom of the set (when two layers are required). Never lock an instrument during autoclaving. This will prevent the steam from reaching and sterilizing the metal-to-metal surfaces. Furthermore, heart expansion during autoclaving can cause cracks in hinge areas. Do not overload the autoclave chamber, as this may also hinder steam penetration. Place a towel on the bottom of the pan to absorb excess moisture during autoclaving. Make sure the towels contain no detergent residue and are neutral pH(7) when immersed in water. (Laundries frequently use inexpensive but high pH(9-13) detergents and do not properly rinse out or neutralize those detergents in the final wash/rinse cycle. Also, sometimes bleaches are added and are not neutralized.) CAUTION— At the end of the autoclave cycle (before the drying cycle) unlock the autoclave door and open it with no more than a crack (about 3/4”). Then run a dry cycle for the period recommended by the autoclave manufacturer. If the autoclave door is opened fully before the drying cycle, cold room air will rush into the chamber, causing condensation on the instruments. This will result in water stains on instruments and also cause wet packs.

Cold Sterilisation:

Most cold sterilization solutions require a 10-hour immersion to render instruments sterile, but this prolonged chemical action may be more detrimental to surgical instruments than the 20-minute autoclave cycle. If the instruments need only to be disinfected (basically clean), cold sterilization is acceptable since disinfection will take place in only 10 minutes. But to render the instruments sterile (with absolutely no living organism surviving), autoclaving is recommended. For instruments with tungsten carbide inserts (needle holders, scissors, tissue forceps), do not use solutions containing benzyl ammonium chloride which will destroy the tungsten carbide inserts.

After Cleaning:

If instruments are to be stored, let them air dry and store them in a clean and dry environment.

Reviews

There are no reviews yet.

Be the first to review “Dumont SS/45 Long Angled Isolating Tweezers”

Delivery

All products are sent from ourselves and not a third party, using our authorised courier/ postal service . We check all orders before despatch to ensure your order arrives as specified and in perfect condition.

Returns

You have 14 days to return an item from the date you received it. To be eligible for a refund your item must be unused and in the same condition that you received it and in the original packaging. You should notify us of your intent to return an item and provide your Order Number reference.

If unwanted item returns arrive in poor or unsaleable condition, a refund will not be possible. You are solely responsible for ensuring that the items in question are returned to us. We will not be liable for returns that are lost in the post or lost for any other reason.

If you receive a faulty or damaged item, we will advise how to return it to us and we will refund the return postage cost. Replacements and / or refunds will only be dispatched / issued on receipt of the returned items.

Refunds

Refunds will only be processed up to 14 days from the sales invoice date. Refunds will be processed within 7 days of product arriving back with us. Payment will be made the same way the product was paid for (PayPal, Bank Transfer or Card payment). No refunds will be issued after 30 days of the sale invoice date.